    digital electronic colposcopy

    Home > Product > digital electronic colposcopy

    BX-8100II digital electronic colposcopy

    Time:2017-06-06

    BX-8100II digital electronic colposcopy

    BX-8100II digital electronic colposcopy

    Working principle:

    Digital electronic colposcopy mainly collects the patient's lesion image information through the color camera. Then it transfers the collected image signal input to the computer for the digital processing, to show the lesion size, shape, location and boundary conditions directly on the computer screen, which provide the doctor with intuitive medical images for diagnosis. The illustrated report card can be generated after computer processing.

    The instrument is equipped with advanced high-speed, high-performance computer digital image management system, with the function of image acquisition, management, display, storage, print. It can store patient information up to tens of thousands of people, which is conducive to the establishment and query of patient information.

    The main technical parameters and features:

    1. Imported 48-million-pixel camera;

    2. CCD horizontal resolution: 480TVL; minimum illumination: 0.21Lx

    Focus distance: 30mm ~ 500mm; Magnification: 1 × ~ 128 ×

    Field of view: 20mm ~ 320mm; depth of field range: 15mm ~ 40mm; 15mm ~ 480mm

    18x optical zoom, 12x digital zoom;

    3. LED light source

    Spot diameter: The diameter of the light source spot in 30cm is not less than 10cm.

    Illumination: no less than 300Lux.

    Temperature rise: no more than 5  per minute.

    4. The instrument resolution

    Resolution is not less than 400TVL.

    5. Portable bracket: can be adjusted up and down, the upper part of the joint can rotate 360 °by manually adjusted, it also can deflect left of right about 90 °, and pitch 45 °forward or backward. Adjustment device is adjustable under manual control and locked after releasing.

    6. Functional requirements

    a) Real-time image acquisition, image freeze;

    b) The system can be continuously collected 1 to 40 images, and has the function of display, freezing, recording, playback, storage, delete the image. the function of dynamic browsing of a number of pictures is applicable;

    c) Calculating and measuring the length, perimeter, and area of the images acquired. The images can be processed by copy, mark, zoom in and out etc.

    d) The instrument has the function of four images contrast in same screen, and single image full screen display;

    e) The instrument has the function of adding, deleting, modifying, retrieving case, and can do query and statistics for medical records and diagnostic results

    f) 8 kinds of print report mode, users can freely edit a variety of reporting mode, generate user templates.

    Instrument standard configuration:

    Computer host: Soyo motherboard, CPU Celeron 430 dual-core 1.8G × 2, 2G memory, 500G hard drive, chassis and Hotan suit, BT878 medical dedicated collection card.

    18.5-inch widescreen LCD monitor; HP color inkjet printer; foot switch (capture image). Digital electronic colposcopy lens;

     

     

     

     

    Working principle:

    Digital electronic colposcopy mainly collects the patient's lesion image information through the color camera. Then it transfers the collected image signal input to the computer for the digital processing, to show the lesion size, shape, location and boundary conditions directly on the computer screen, which provide the doctor with intuitive medical images for diagnosis. The illustrated report card can be generated after computer processing.

    The instrument is equipped with advanced high-speed, high-performance computer digital image management system, with the function of image acquisition, management, display, storage, print. It can store patient information up to tens of thousands of people, which is conducive to the establishment and query of patient information.

    The main technical parameters and features:

    1. Imported 48-million-pixel camera;

    2. CCD horizontal resolution: 480TVL; minimum illumination: 0.21Lx

    Focus distance: 30mm ~ 500mm; Magnification: 1 × ~ 128 ×

    Field of view: 20mm ~ 320mm; depth of field range: 15mm ~ 40mm; 15mm ~ 480mm

    18x optical zoom, 12x digital zoom;

    3. LED light source

    Spot diameter: The diameter of the light source spot in 30cm is not less than 10cm.

    Illumination: no less than 300Lux.

    Temperature rise: no more than 5  per minute.

    4. The instrument resolution

    Resolution is not less than 400TVL.

    5. Portable bracket: can be adjusted up and down, the upper part of the joint can rotate 360 °by manually adjusted, it also can deflect left of right about 90 °, and pitch 45 °forward or backward. Adjustment device is adjustable under manual control and locked after releasing.

    6. Functional requirements

    a) Real-time image acquisition, image freeze;

    b) The system can be continuously collected 1 to 40 images, and has the function of display, freezing, recording, playback, storage, delete the image. the function of dynamic browsing of a number of pictures is applicable;

    c) Calculating and measuring the length, perimeter, and area of the images acquired. The images can be processed by copy, mark, zoom in and out etc.

    d) The instrument has the function of four images contrast in same screen, and single image full screen display;

    e) The instrument has the function of adding, deleting, modifying, retrieving case, and can do query and statistics for medical records and diagnostic results

    f) 8 kinds of print report mode, users can also freely edit a variety of reporting mode, generate user templates.

    Instrument standard configuration:

    Computer host: Soyo motherboard, CPU Celeron 430 dual-core 1.8G × 2, 2G memory, 500G hard drive, chassis and Hotan suit, BT878 medical dedicated collection card.

    18.5-inch widescreen LCD monitor; HP color inkjet printer; foot switch (capture image). Digital electronic colposcopy lens;

     


    Add:Xuzhou High - tech Industrial Development Zone, the third industrial park north longitudinal three middle east
    Tel:+86-0516-85619889 Fax:0516-85610698、61889880

    All rights reserved:Microwave treatment instrument | Anorectal examina Technical Support:Qingfeng Technology ICP 11042540

    一级A片自慰女人自慰看片
  • <small id="swoym"><li id="swoym"></li></small><small id="swoym"></small>
  • <small id="swoym"><li id="swoym"></li></small>
  • <small id="swoym"><li id="swoym"></li></small>
  • <li id="swoym"></li>
  • <div id="swoym"><button id="swoym"></button></div>
  • <div id="swoym"></div><div id="swoym"><li id="swoym"></li></div>
  • <small id="swoym"><li id="swoym"></li></small>