Function:
2. Ankle Brachial Pressure Index (ABI)
Characteristic:
1、Pulse Wave Velocity, (PWV)
(1)、PWV(Pules Wave Velocity):
PWV calculated formula and clinic assessment standard:
PWV = distance/time difference(Δt)
(2) Clinical significance
The reduction of arterial elasticity is the composite reaction of early vascular wall damage that is caused by various cardiovascular risk factors. It not only the early vascular pathological markers with high specificity and sensitivity, but a king of high risk factor, which take part in the evolution and occurrence of cardiovascular disease. Therefore, the non-invasive measurement of the Artery elastic functional system examination has been a popular research topic. The pulse wave velocity measurement is regular indicator of the non-invasive measurement of the Artery elastic functional system examination. PWV, as a non-invasive measurement, can early detect dysfunctions of the artery, and synthetically reflect various risk factors of vascular damage.
(3) The range of normal and abnormal PWV value
The value of PWV increases with the increase of age, its reference Value is 1400cm/s.
According to assessment of American College of Cardiology medical scientific report (1993):
l PWV<1400cm/s: normal value.
l 1400cm/s ≤ PWV ≤ 1800cm/s: mild peripheral arteriosclerosis.
2. Ankle Brachial Pressure Index (ABI)
(1) ABI =
(2) Clinical significance
The use of ABI can help to non-invasively assess the open of lower limb arterial blood vessels, and can predict a variety of cardiovascular and cerebrovascular events, it is more accurate and more objective to measure arteriosclerosis than applying a single PWV value. This is because, if the arterial is stenosis or occlusion, the pulse wave will be blocked in the occlusion site, so the pulse wave transmission will slow down. At this time, regardless of the extent of arteriosclerosis, PWV sometimes may always show a normal or lower value, which mislead the diagnosis of disease. While the ABI will be significantly reduced. From the value of ABI, we can find the occlusion of lower extremity arteries. Therefore, the ABI index can be used as a complement to PWV, which provide more comprehensive prediction of arteriosclerosis.
In normal situation, ABI≥1. If ABI<1, lower extremity artery may have stenosis occlusive lesions. If ABI<0.5, lower extremities have severe ischemia. If conditions permit, lower extremity blood supply should be reconstructed in time.
(3) Normal ABI range is 0.9 - 1.4
ABI value | Possible pathology |
ABI<0.9 | Peripheral arteries of the lower extremities have a risk of hardening or diameter narrowing, peripheral arteria disease (PAD). |
ABI<0.8 | Peripheral arteries of the lower extremities have a considerable risk of hardening or tube diameter narrowing, peripheral arteria disease (PAD). |
0.5<ABI<0.8 | A part of the peripheral arteries of the lower limbs may have been completely blocked, peripheral arteria disease (PAD). |
ABI<0.5 | The peripheral arteries of the lower limbs may have multiple complete occlusions, peripheral arteria disease (PAD). |
ABI>1.3 | Lower extremity vascular calcification. |
PACKING LIST
TYPE BX-5100A ARTERIOSCLEROSIS DETECTING SYSTEM
No. | Name | Unit Quantity | Note |
1 | Cart | 1 Unit | |
2 | Cart Bracket | 1 Unit | |
3 | Host | 1 Unit | |
4 | Monitor | 1 Unit | |
5 | Monitor Bracket | 1 Set | |
6 | Keyboard & Mouse | 1 Unit | Mouse Pad Provided |
7 | PWV Probe | 1 Set | 4 Units of HK-2000B Sensor |
8 | Blood Pressure Cuff | 1 Unit | 1 Unit of Regular Size |
9 | Serial Port Line | 1 Thread | |
10 | Foot Switch | 1 Unit | |
11 | Printer | 1 Unit | |
12 | Printing Paper | 1 Unit | |
13 | Tape Measure | 1 Unit | |
14 | Patch Cord | 3 Threads | |
15 | Ground Wire | 1 Thread | |
16 | Fuse | 2 Units | |
17 | 3 Certificates | 1 Set | Effective with Original Official Stamps only |
18 | Certificate of Conformity | 1 Unit | |
19 | Instructions | 1 Unit | |
20 | Warranty Card | 1 Unit | |
21 | User Registration Form | 1 Unit | |
22 | Delivery & Installation Records | 1 Unit | |
23 | Customer Satisfaction Survey | 1 Unit |